- Home
- Private Series
- Carbon dioxide lattice system · DM-802
Carbon dioxide lattice system · DM-802
It uses a scanning lattice method to emit energy to form a repair area composed of action lattices and intervals on the epidermis. Each action point consists of a single or several high-energy pulses, which can directly penetrate into the dermis and vaporize away wrinkles or wrinkles in an instant. At the same time, it stimulates the hyperplasia of collagen, and then initiates a series of skin reactions such as tissue repair and collagen reorganization. Under the action of energy, collagen fibers shrink by about one-third, fine wrinkles are flattened, deep wrinkles become shallower and thinner, and the skin becomes firm and shiny.
Carbon dioxide lattice system · DM-802
It uses a scanning lattice method to emit energy to form a repair area composed of action lattices and intervals on the epidermis. Each action point consists of a single or several high-energy pulses, which can directly penetrate into the dermis and vaporize away wrinkles or wrinkles in an instant. At the same time, it stimulates the hyperplasia of collagen, and then initiates a series of skin reactions such as tissue repair and collagen reorganization. Under the action of energy, collagen fibers shrink by about one-third, fine wrinkles are flattened, deep wrinkles become shallower and thinner, and the skin becomes firm and shiny.
|
Technical Parameters
|
|
|---|---|
|
Name
|
DM-802
|
|
Power
|
600W
|
|
Wavelength
|
10600nm
|
|
Scan range
|
20mm x 20mm/mj
|
|
Dot matrix power
|
60W
|
|
Scan speed
|
>10m/s
|
|
Ambient temperature
|
5°C ~ 40°C
|
|
Handle size
|
450mm
|
|
Output graphics
|
Circle, triangle, rhombus, square, etc.
|
|
Package Size
|
61x51x126cm
|
|
Weight
|
55KG
|
Three-dimensional lattice technology is used to change the non-surgical output mode and act on the skin in the form of lattice. Use CO2 lattice metal tube non-invasive mode for care. Precise temperature control conditions, practicalCollagen shrinks, reorganizes and regenerates.
3D lattice technology
Precise temperature control and deep control conditions
Gold-plated 360° reflective handpieces
Easy to operate
The private system tightens using CO2 lattice metal tube non-invasive mode for care. Ensures that the tissue temperature can be maintained within a carefully controlled depth of 200-500um
to reach (50-70℃) to obtain ideal collagen shrinkage and reweighting The purpose of tissue regeneration is to achieve long-lasting vaginal tightening effect. water It is the main component of vaginal mucosa. The private wavelength is 10600nm, This wavelength is at the peak of the water absorption curve, i.e. the moisture in the mucous membrane can Very good at absorbing energy and converting it into heat energy. Due to the high degree of moisture that can be The absorption depth is very shallow, about 3um, so it will not cause any damage to the vaginal wall. cause damage. Intimate lasers are great for heating the vaginal walls.




